Test Method: SATRA TM277

Determination of organotins

December 2020

SCOPE

This test method is intended to determine the levels of a range of common organotin compounds in a material. The method is applicable to all types of material.

PRINCIPLE

Organotins are extracted from the test specimen using an ethanol/methanol mixture and are then converted to the corresponding tetraalkyl derivative through a reaction with sodium tetraethylborate. The derivatised organotins are identified and quantified using a gas chromatography/mass spectrometry detection technique.

REFERENCES

EN ISO 1042 – Laboratory glassware. One-mark volumetric flasks.
EN ISO 648 – Laboratory glassware. Single volume pipettes.

HISTORY

First issued January 2004. Revised February 2011, December 2020.

AVAILABILITY

This test method is available to members and non-members.

PRICE (ex. VAT)

This price is for a printed copy of the Test Method.

  • Members: £75
  • Non-members: £215